Follow:
| High-Low Temperature(Humidity) Fast Change Rate Chamber | |||||
| Model | JT/JC250(CL)-5ES | JT/JC500(CL)-5ES | JT/JC1000(CL)-5ES | JT/JC2000(CL)-5ES | |
| JT/JC250(CL)-10ES | JT/JC500(CL)-10ES | JT/JC1000(CL)-10ES | JT/JC2000(CL)-10ES | ||
| JT/JC250(CL)-15ES | JT/JC500(CL)-15ES | JT/JC1000(CL)-15ES | JT/JC2000(CL)-15ES | ||
| JT/JC250(CL)-20ES | JT/JC500(CL)-20ES | JT/JC1000(CL)-20ES | JT/JC2000(CL)-20ES | ||
| JT/JC250(CL)-25ES | JT/JC500(CL)-25ES | JT/JC1000(CL)-25ES | JT/JC2000(CL)-25ES | ||
| Nominal inside volume(L) | 250 L | 500 L | 1000 L | 2000 L | |
| Performance | Temperature range | -70℃~+150℃ | |||
| Humidity range | 20%~98%R.H. (Humidity working range+20℃~+85℃, please refer to the temperature and humidity range diagram for details) | ||||
| Temperature fluctuation | ≤±0.5℃ | ||||
| Temperature uniformity | ≤2℃ | ||||
| Temperature deviation | ≤±2℃ | ||||
| Humidity deviation | -3~+2%R.H.(75%R.H.above), ±5%R.H.(75%R.H.below) | ||||
| Heating rate (Average/ linear, -55~+85℃) | 5℃/min;10℃/min;15℃/min;20℃/min;25℃/min | ||||
| Cooling rate (Average/ linear, -55~+85℃) | |||||
| Remarks | Above indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017) | ||||
| Internal dimension(mm)D*W*H | 5ES | 500*700*750 | 700*850*850 | 1000*1000*1000 | 1400*1200*1200 |
| 10/15ES | 500*700(/750)*750 | 700*850*850 | 900*1150*1000 | 1100*1400*1300 | |
| 20ES | 450*750*750 | 600″850*850 | 800*1150*1000 | 1000*1400*1300 | |
| 25ES | 450*750*750 | 600*850*850 | 800*1150*1000 | 1000*1400*1300 | |
| External dimension(mm)D*W*H | 5ES | 1800*950*1800 | 1850*1100*1900 | 2100*1250*2100 | 2500*1450*2400 |
| 10ES | 1800*950*1800 | 2200*1100*2100 | 2300*1400*2500 | 3000*1550*2100 | |
| 15ES | 2200*1000*2100 | 2500*1450*2350 | 2700*1400*2600 | 3500*1950*2100 | |
| 20ES | 2200*1000*2100 | 25001450*2350 | 2700*1400*2600 | 3500*1950*2100 | |
| 25ES | 2300*1000*2100 | 2600*1450*2350 | 2900*1400*2600 | 4000*1950*2100 | |
| Caster | 4 -6 casters | ||||
| Inspection window | 450*450 Equipped with heating device to prevent condensation and frost formation | ||||
| Test hole | 1 Φ100 | 2Φ100 | |||
| Stainless steel shelf (2 pcs in standard configuration) | Bearing 25kg/pc | Bearing 50kg/pc | |||
| Using environment temperature | 0~40℃ | ||||
| Shell | Sprayed steel plate | ||||
| Interior | SUS304 stainless steel | ||||
| Cooling mode | water-cooling, (water temperature 7~28℃,hydraulic pressure 0.2~0.5Mpa,To ensure cooling performance) | ||||
| Controller | 7′ Color touch screen Controller | ||||
| Communication function | RS485 or standard RJ45 network interface, standard USB interface | ||||
| Power supply | 380V+10%/ 50HZ+1,three-phase-five-wire system (3P+N+G) | ||||
| Meet the testing method | GB2423.1-2008、GB2423.2-2008、GB2423.3-2008; GB2423.4-2008、GJB150.3-2009、GJB150.4-2009、GJB150.9-2009 | ||||
| Safety precautions | Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heaters, Refrigerator overpressure/ overload/ oil shortage protection; Humidifier fault protection; Overload/ overheating protection for blower motor; Control board overcurrent protection, leakage protection; Cooling water shortage protection, etc. | ||||
| Optional | 1. Optional special test holes and special shelves; 2. Can remove the wet and hot function (model JT * CES); 3. Optional Dry air blowing system; 4. Optional liquid nitrogen function. | ||||