Categories: Low Pressure Enviromental Test Chamber
Follow:
| High-Low Temperature and Low Pressure Vacuum Chamber | ||||||
| Model | JTP250(C) | JTP500(C) | JTP1000(C) | JTP2000(C) | ||
| Nominal inside volume(L) | 250L | 500L | 1000L | 1000L | ||
| Performance | Temperature range | -40℃~+150℃ for model without suffix C, -70℃~+150℃ for model with suffix C | ||||
| Temperature fluctuation | ≤±0.5 (Under atmospheric pressure) | |||||
| Temperature uniformity | ≤2℃ | |||||
| Temperature deviation | ≤±2℃ (Under atmospheric pressure) | |||||
| Heating rate(average) | 2℃/min | 2℃/min | 2℃/min | 2℃/min | ||
| Cooling rate(average) | 1℃/min | 1℃/min | 1℃/min | 1℃/min | ||
| Remarks | Above indicators are measured in no load at ambient temperature of 20±2°C (According to GB/T 5170.2-2017) | |||||
| Air pressure range | Ventricular pressure~0.5kPa | |||||
| Air pressure error | ±2kPa(≥40kPa), ±5%(2kPa~40kPa), ±0.1kPa(≤2kPa) | |||||
| Pressure reduction time | Under atmospheric pressure~1kPa,nearly 30min | |||||
| Pressure recovery time | ≤10kPa/min | |||||
| Internal dimension(mm) | D*W*H | 550*600*750 | 700*800*900 | 1000*1000*1000 | 1400*1200*1200 | |
| External dimension(mm) | D*W*H | 2000*1060*1900 | 2500*1260*2050 | 2720*1460*2050 | 3150*1650*2050 | |
| Test hole | 1 Φ100 | 2Φ100 | ||||
| Stainless steel shelf (2 pcs in standard configuration) | Bearing 20kg/pc | Bearing 50kg/pc | ||||
| Using environment temperature | 0~+40℃ | |||||
| Shell | Sprayed steel plate | |||||
| Interior | SUS304 stainless steel | |||||
| Cooling mode | water-cooling,(water temperature 7~28℃,hydraulic pressure 0.2~0.4Mpa, To ensure cooling performance) | |||||
| Controller | 7′ Color touch screen Controller | |||||
| Communication function | RS485 or standard RJ45 network interface, standard USB interface | |||||
| Gas source | Crushing air 0.4~0.7MPa | |||||
| Installed capacity(kw)(-/-C) | 14/17 | 19/24 | 28/34 | 33/42 | ||
| Weight(kg) | 1000 | 2000 | 3000 | 4500 | ||
| Power supply | 380V+10%/50HZ+1, three-phase-five-wire system (3P+N+G) | |||||
| Meet the testing method | GB2423.1-2008, GB2423.2-2008, GB2423.21-2008, GJB150.3-2009, GJB150.4-2009, GJB150.2-2009 (except for rapid bucking), GJB150.6-2009 | |||||
| Safety precautions | Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heater refrigerator overpressure/ overload protection; Overload/ overheating protection for blower motor; Control board overcurrent protection and leakage protection, vacuum pump overload protection, compressed air undervoltage protection. | |||||
| Optional | Special test holes, aviation plugs, terminals, special shelves, etc., optional with 15s quick decompression and 0.1s explosive decompression | |||||

Copyright © 2024 SICHUAN JUPITER TECHNOLOGY CO.,LTD. All Rights Reserved Privacy Policy
message