IntroductionHigh – low temperature and low pressure test chamber is a simulation of high altitude, high altitude, (plateau area) climate for storage and transport reliability test, and can be simultaneously electrified on the test piece for electrical performance parameters of the test equipment. Applicable to the defense industry, aerospace industry automation components, automotive parts, batteries, flat panel display group industry and related products for high temperature, low temperature, height (not higher than 30,000 m above sea level or 45,000 m) and high and low temperature cycling test, temperature and altitude of the integrated test, high and low temperature test this chamber can be used for heat dissipation test specimens and non-heat dissipation test specimen test.Safety & ProtectionsPower supply under-voltage, over voltage, missing phase, phase sequence error protection; 3 kinds of overtemperature protection Heater short circuit protection; Compressor overpressure/ overload/ protection: Humidifier fault protection: Blower Motor overload/overheat protection; Panel over current protection, earth leakage protection: Vacuum pump overload protection: compressed air inadequate pressure protection.ApplicationMainly used in aviation, aerospace, information, electronics and other fields to determine the instrumentation, electronic products, materials, components, equipment, etc. under the single or simultaneous condition of low pressure, high temperature, low temperature for environmental adaptability and reliability test or measured technical data of samples.OptionsSpecial cable port;
Electric interlock,terminals;
Special shelf
High-Low Temperature and Low Pressure Vacuum Chamber
Model
JTP250(C)
JTP500(C)
JTP1000(C)
JTP2000(C)
Nominal inside volume(L)
250L
500L
1000L
1000L
Performance
Temperature range
-40℃~+150℃ for model without suffix C, -70℃~+150℃ for model with suffix C
Temperature fluctuation
≤±0.5 (Under atmospheric pressure)
Temperature uniformity
≤2℃
Temperature deviation
≤±2℃ (Under atmospheric pressure)
Heating rate(average)
2℃/min
2℃/min
2℃/min
2℃/min
Cooling rate(average)
1℃/min
1℃/min
1℃/min
1℃/min
Remarks
Above indicators are measured in no load at ambient temperature of 20±2°C (According to GB/T 5170.2-2017)
Air pressure range
Ventricular pressure~0.5kPa
Air pressure error
±2kPa(≥40kPa), ±5%(2kPa~40kPa), ±0.1kPa(≤2kPa)
Pressure reduction time
Under atmospheric pressure~1kPa,nearly 30min
Pressure recovery time
≤10kPa/min
Internal dimension(mm)
D*W*H
550*600*750
700*800*900
1000*1000*1000
1400*1200*1200
External dimension(mm)
D*W*H
2000*1060*1900
2500*1260*2050
2720*1460*2050
3150*1650*2050
Testhole
1 Φ100
2Φ100
Stainless steel shelf (2 pcs in standard configuration)
Bearing 20kg/pc
Bearing 50kg/pc
Using environment temperature
0~+40℃
Shell
Sprayed steel plate
Interior
SUS304 stainless steel
Cooling mode
water-cooling,(water temperature 7~28℃,hydraulic pressure 0.2~0.4Mpa, To ensure cooling performance)
Controller
7′ Color touch screen Controller
Communication function
RS485 or standard RJ45 network interface, standard USB interface
Gas source
Crushing air 0.4~0.7MPa
Installed capacity(kw)(-/-C)
14/17
19/24
28/34
33/42
Weight(kg)
1000
2000
3000
4500
Power supply
380V+10%/50HZ+1, three-phase-five-wire system (3P+N+G)
Meet the testing method
GB2423.1-2008, GB2423.2-2008, GB2423.21-2008, GJB150.3-2009, GJB150.4-2009, GJB150.2-2009 (except for rapid bucking), GJB150.6-2009
Safety precautions
Power supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Short circuit protection for heater refrigerator overpressure/ overload protection; Overload/ overheating protection for blower motor; Control board overcurrent protection and leakage protection, vacuum pump overload protection, compressed air undervoltage protection.
Optional
Special test holes, aviation plugs, terminals, special shelves, etc., optional with 15s quick decompression and 0.1s explosive decompression