ВведениеThe hydrogen pre cooling device is an advanced equipment specifically designed to provide relevant testing for hydrogen fuel cell systems. Its main function is to achieve pre cooling or preheating of hydrogen, providing the required temperature of hydrogen for hydrogen fuel cell systems. Jupiter can provide the hydrogen temperature control function required for climate and environmental testing of hydrogen fuel cell systems with power ranging from 1KW to 300KW and higher, ensuring that the gas temperature is consistent with environmental conditions during the testing process, thereby ensuring the accuracy and reliability of the test.
The core advantage of the oxygen temperature control device is that it can accurately control the hydrogen temperature required by the fuel cell system to the level consistent with climate and environmental tests, avoiding the problem of test data distortion caused by inconsistent hydrogen supply temperature and environmental temperature.КэйтыгнидыСистема охлаждения:отвечает за снижение температуры газообразного водорода, чтобы обеспечить необходимый эффект предварительного охлаждения.Система подогрева термомасляного масла:используется для точного контроля температуры газообразного водорода и обеспечения его соответствия испытательной среде.Система управления:интеллектуально управлять и контролировать все устройство, чтобы обеспечить стабильность и безопасность процесса тестирования
JHP Series Hydrogen Pre Cooling Unit
Model
JHP2-T
JHP3-T
JHP4-T
JHP5-T
JHP6-T
JHP7-T
JHP8-T
Hydrogen flow rate
2000NLPM
3000NLPM
4000NLPM
5000NLPM
6000NLPM
7000NLPM
8000NLPM
Temperature range
-40℃~80℃
Dimensions (D*W*H)
Nearly 1800mm*1000mm*2600mm
Nearly 2250mm*1250mm*2600mm
Nearly 2400mm*1250mm*2600mm
Installed power
17Kw
25Kw
33Kw
38Kw
45Kw
56Kw
Maximum operating current
23A
34A
48A
50A
60A
76A
Cooling water flow rate
4m³/h
5m³/h
6m³/h
7m³/h
9m³/h
12m³/h
Interface type
External wire G1
External wire G2 1/2
External wire G2
Weight
1000Kg
11000Kg
1300Kg
1500Kg
1800Kg
ВведениеIn the field of hydrogen energy detection, the hydrogen air pre cooling device is a key equipment used in the testing process of hydrogen fuel cell stacks. Its main function is to provide pre cooling or preheating of hydrogen and air for fuel cell stacks, ensuring the detection of performance indicators of fuel cell stacks under different environmental conditions.
The JHAP pre cooling device can be applied to hydrogen fuel cell stacks of 1KW to 300KW and higher power, providing precise climate and environmental testing support. Its core advantage lies in its ability to precisely adjust the temperature of hydrogen and air to maintain consistency with the ambient temperature of the fuel cell stack, thereby avoidingthe problem of affecting the test results due to gas temperature distortion.ПримечаниеТребования к подаче водорода и воздуха:
The dry bulb temperature of hydrogen and air should be ensured to be below 30 ℃;
The dew point temperature of hydrogen and air should be ensured to be below -55 ℃;
Providing low dew point hydrogen and air is the key to ensuring stable system operation, which can effectively prevent gas from entering the plate heat exchanger and damaging it due to condensation and icing.
JHAP Series Hydrogen & Air Pre Cooling Unit
Model
JHAP26-T
JHAP39-T
JHAP412-T
JHAP515-T
JHAP618-T
JHAP721-T
JHAP824-T
Hydrogen flow rate
2000NLPM
3000NLPM
4000NLPM
5000NLPM
6000NLPM
7000NLPM
8000NLPM
Air flow rate
6000NLPM
9000NLPM
12000NLPM
15000NLPM
18000NLPM
21000NLPM
24000NLPM
Temperature range
-40℃~80℃
Dimensions (D*W*H)
Nearly 2250mm*1250mm*2650mm
Nearly 2400mm*1400mm*2800mm
Nearly 2700mm*1700mm*3000mm
Installed power
45Kw
55Kw
70Kw
85Kw
98Kw
110Kw
138Kw
Maximum operating current
60A
71A
92A
110A
130A
148A
186A
Cooling water flow rate
12m³/h
14m³/h
18m³/h
21m³/h
25m³/h
28m³/h
36m³/h
Interface type
External wire G1 1/2
External wire G2
External wire G2 1/2
External wire G2
External wire G2 1/2
Weight
1500Kg
1800Kg
2200Kg